Skip to content

D7D12L12 Series Firmware ​

This is the V2.1 firmware update for performance improvement and stabilization of the mightyZAP Force Control lineup (Model name 12Lf) products.

  • Update Target: All 12Lf models
  • Update Version: V2.1 (Final update: February 28, 2022)
  • Key Changes: Bug fixes and improved stability (Includes V2.0 improvements such as MODBUS RTU support)

Essential Preparations Before Update ​

Before proceeding with the update, please prepare the following items.

Important Precautions ​

Please read the following precautions for a safe and smooth update.

  • Equipment Testing Mandatory: If the firmware of an actuator applied to existing equipment has been updated, you must perform an equipment test again to ensure there are no problems with the operation characteristics.
  • Correct Model Selection: You must install the firmware that matches the model name of the actuator you own. If you accidentally installed a different firmware, you can proceed with the update again with the correct firmware.
  • Individual Updates: Actuators must be updated one by one. Updating multiple units at the same time may cause errors.
  • Check Connection Cables: Do not touch the communication and power lines between the PC, interface, and actuator during the update. If a communication error occurs, please refer to the manual and retry.
  • Change in Calibration Procedure: In versions V2.0 or higher, the Stroke Calibration procedure is skipped after the update is complete.

Firmware Download ​

Check the model name of your product and download the V2.1 firmware from the link below.

ModelVersionDownload
L12-12F-3V2.0 ➔ V2.1⬇️Download
L12-12PT-3⬇️Download
L12-20F-3⬇️Download
L12-20PT-3⬇️Download
L12-40F-3⬇️Download
L12-40PT-3⬇️Download
L12-64F-3⬇️Download
L12-64PT-3⬇️Download
L12-100F-3⬇️Download
L12-100PT-3⬇️Download

Release Notes (Change History) ​

V2.1 Changes (2022-02-28) ​

  • Fixed a bug where Min/Max Position Calibration function was not saved after reset
  • Fixed a bug where saving was intermittently impossible after setting Current Limit

V2.0 Changes (2021-10-06) ​

  • Major Feature Additions and Improvements

  • Expansion of Communication Protocol: Supports MODBUS RTU protocol (Selectable with IR Open Protocol)

  • Additional Communication Speed Option: Added Baudrate 38400 - Added User Setting Function: Start/End points can be set with the Min/Max Position Calibration function

  • Stability and Convenience Improvements

  • Improved Booting Stability: Prevents slippage by immediately turning Force Enable ON when power is applied

  • Ensured Communication Stability: Changed Return Delay to a fixed value based on Baudrate

  • Strengthened System Stability: Stroke Pulse width and Center Difference parameters cannot be changed (Fixed values)

  • Simplified Error Indication: Simplified error status indication from 7 types to 2 types, and LED colors to RED solid/blinking - Improved Setting Convenience: Changed Compliance Margin to a non-volatile parameter to maintain the set value even after power is cut off.