12Lf Series Firmware

mightyZAP Force Control Lineup (Model: 12Lf) V2.1 Firmware Update

This is the V2.1 firmware update for performance improvement and stabilization of the mightyZAP Force Control lineup (Model: 12Lf).

  • Target Models: All 12Lf models
  • Update Version: V2.1 (Last updated: February 28, 2022)
  • Key Changes: Bug fixes and stability improvements (includes V2.0 enhancements such as MODBUS RTU support).

Prerequisites for Update

Before proceeding with the update, please ensure you have the following items ready.

Important Precautions

Please read the following precautions carefully to ensure a safe and smooth update.

  • Mandatory Equipment Test: After updating the firmware of an actuator already installed in your equipment, you must conduct an equipment test again to verify that there are no issues with its operational characteristics.
  • Correct Model Selection: You must install the firmware that matches the model name of your actuator. If you accidentally install the wrong firmware, you can simply update it again with the correct one.
  • Individual Updates: Actuators must be updated one at a time. Attempting to update multiple units simultaneously may cause errors.
  • Check Connections: Do not touch the communication and power cables connecting the PC, interface, and actuator during the update. If a communication error occurs, please refer to the manual and try again.
  • Change in Calibration Procedure: For V2.0 and later versions, the Stroke Calibration procedure is omitted after the update is complete.

Firmware Download

  • Please refer to the old and new firmware number for each actuator model.
  • The firmware version number can be found on the mightyZAP manager software. Connect your actuator with the software, then see the "Management" -> "Information" window or "System" -> "Firmware version".
  • If your firmware version is an older version, please update it for better performance.
ModelVersionDownload
12Lf-12F-27V2.0V2.1⬇️Download
12Lf-12PT-27⬇️Download
12Lf-20F-27⬇️Download
12Lf-20PT-27⬇️Download
12Lf-35F-27⬇️Download
12Lf-35PT-27⬇️Download
12Lf-55F-27⬇️Download
12Lf-55PT-27⬇️Download
12Lf-100F-27⬇️Download
12Lf-100PT-27⬇️Download

Release Notes (Changelog)

V2.1 Changes (2022-02-28)

  • Resolved an issue where Min/Max Position Calibration data failed to save after a reset. (Saved Min/Max Position Calibration data is now retained even after a reset).
  • Fixed a save failure issue that occurred after setting the Current Limit.

V2.0 Changes (2021-10-06)

  • Major Feature Additions and Improvements
    • Expanded Communication Protocol: Added support for the MODBUS RTU protocol (selectable with IR Open Protocol).
    • Additional Communication Speed Option: Added 38400 Baudrate.
    • Added User Configuration Feature: Start/end points can now be set using the Min/Max Position Calibration feature.
  • Stability and Convenience Improvements
    • Improved Boot-up Stability: Prevents drifting by immediately turning ON with Force Enable upon power-up.
    • Ensured Communication Stability: Changed Return Delay to a fixed value dependent on the Baudrate.
    • Enhanced System Stability: Stroke Pulse width and Center Difference parameters are now fixed and cannot be changed.
    • Simplified Error Indication: The error status display has been simplified from 7 types to 2, with the LED color simplified to solid/blinking RED.
    • Improved Configuration Convenience: Changed Compliance Margin to a non-volatile parameter to retain its value even after power is turned off.