17Lf-xxF-87 Datasheet

1 Features

  • Micro size
  • Precise position control & feedback
  • Stall Force control by current feedback
  • Speed control (1000 resolution)
  • Strong force comparing to the size
  • Built-in Drive Circuitry
  • RS-485 communication
  • MODBUS RTU Protocol
  • Extended I/O Port
  • Action function (No coding)
  • Parameter programmable on the Manager software

2 Specification

2.1 Common Specifications

PropertyValue
Stroke87mm
Rated Load17N⁓50N according to leadscrew pitch
Recommended duty cycle at rated loadunder 50%
Micro controller32bit Arm Cortex
Position Resolution10000 Resolution (A/D Converter)
Input Voltage12.0V(Rated), 8V ⁓ 13 V(Operating)
Motor Type / WattCoreless DC Motor / 3.8 Watt
Current consumption30mA(Idle), 400mA(Rated), 1.6A(Stall)
Position repeatabilityUnidirectional less than +/-0.05mm(50um)
Bydirectional less than +/-0.1mm(100um)
Current Tolerance±15% at Over 50mA
Position sensor10kΩ linearity potentiometer
Size, Weight86.8(L)x 57.9(W)x 23(H)mm / 113.5g [+/-5%]
CommunicationRS-485
ProtocolMODBUS RTU
Operating Temperatures-10℃ ⁓ 60℃
Ingress protectionIP54
Mechanical Backlash0.03mm(30um)
Audible NoiseMax. 50db at 1m
Gear ratio9.6 : 1
Gear typeEngineering Plastic
Rod typeStaniless Steel Rod
Standard Accessory1xHinge base
1x Hinge
1xHinge shaft
1xRod end tip
2x M3 NUT
3 x M2.5x6 screws
1x RS485 Molex wire harness (200mm)
1 x Extended I/O Molex wire harness (200mm)
1 x M3 spanner
1 x Socket set screw
Connector Type (Male) in the ActuatorMOLEX 53253-0470
Wire HarnessMolex(51065-0400) to Molex(51065-0400)/ 200mm / 0.08x60(22AWG)
Extended I/O Wire HarnessMolex 510210500, 5pins / 200mm length, 0.16 x 7 (26AWG)

2.2 Voltages

ParameterMinNormMaxUnitNote
Supply voltage81213V
Logic input voltage-7.0-12.0VRS-485 D-, D+

2.3 Currents

ParameterMinNormMaxUnitNote
Maximum peak Current≤1.7AStall Current
No Load Current≤300mANo Load
Rated Load Current≤400mAat over Goal current800mA setting
Max Applicable Load Current≤600mAat Goal current 1.6Asetting
Idle Current≤30mA

2.4 Temperatures

ParameterMinNormMaxUnitNote
StorageTemp.-20-70
Operating Temp.-10-60

2.5 Strokes

ParameterMinNormMaxUnitNote
MIN Position4.58.08.5mm
MAX Position94.595.095.5mm
Stroke length87.0mm
  • Min/Max position values ​​can be synchronized using the "Min/Max Position Calibration" function on the Manager software or parameter coding.

2.6 No Load Speed

ParameterMinNormMaxUnitNote
Maximum Speed at 12.0V94.5105.0115.5mm/s17Lf-17F-87
73.882.090.2mm/s17Lf-27F-87
25.228.030.8mm/s17Lf-50F-87

2.7 Load

ParameterRatedUnitNote
Load at 12.0V17N17Lf-17F-87
3.82lbf
1.73kgf
27N17Lf-27F-87
6.07lbf
2.75kgf
50N17Lf-50F-87
11.24lbf
5.10kgf

2.8 Self Lock Feature

ParameterMinNormMaxUnitNote
Self LockN/A-17Lf-17F-87
-N/A-17Lf-27F-87
-Available-17Lf-50F-87

3 Reference Data

3.1 Voltage Vs Speed

The graph of the speed change according to the input voltage at no-load condition. This data contains errors, so please use it for reference only. 87_voltageVSspeed

Note

Tested at Goal Current 800.

3.2 Voltage Vs Stall Force

The Stall Force graph according to the input voltage. This data contains errors, so please use it for reference only. 87_voltageVSforce

Note

Tested at Goal Current 800.

CAUTION

The error for each Force value is +/- 15%.

3.3 Goal Speed Vs Speed

No-load speed according to the change in the Goal Speed parameter value. Depending on the load, the maximum speed may be reduced or the time to reach maximum speed may be longer. 87_goalspeedVSspeed

Note

Tested at Goal Current 800.

3.4 Goal Current vs Stall Force

The Stall Force for the Goal Current setting value. 87_goalcurrentVSstallforce The Stall Force is measured by minimizing the speed value to measure only the force for pure current values.

CAUTION

The error of the Stall Force value corresponding each Goal Current value is +/- 15%. The areas marked in red has a relatively large error due to the internal load (for 200mA or less) and heat generation (for 1100mA or more), so please use it only for reference. If a continuous load occurs and a current of 1A or more flows, the current value gradually decreases and converges to 1A, and if the overload protection function is activated, an overload alarm and shutdown occur within several seconds.

TIP

This data represents the power of the DC motor, and we recommend users to set the Goal current to 3 times the actual load applied to the actuator. The smaller the difference between the actual load and the power produced by the motor, the slower the motor speed will be, and if they are the same, the motor will not move.

CAUTION : Setting the maximum allowable load (twice the rated load)

Maximum allowable load is the twice the rated load. In this case, the Duty Rate must be lower than 20%. EX>

LoadGoal CurrentDuty rateLoadGoal CurrentDuty Rate
20N(Rated)800Max. 50%35N(Rated)800Max. 50%
40N(Max)1600Max. 20%70N(Max)1600Max. 20%

3.5 Goal Current vs Speed

The speed change of mightyZAP for the Goal Current setting value at rated load. 87_goalcurrentVSspeed For rated load speed, it shows about 80 to 90% of the no-load maximum speed depending on the model.

Note

Measured under rated load.

CAUTION

Speed Data has an error of about +/-10%. The area marked in red is where the Stall Force at the corresponding Goal Current setting and the rated load are similar, so mightyZAP may not move. Please use it for reference only.

3.6 PIN Map

3.6.1 RS-485 PIN Map
3.6.1.1 PIN MAP Table
PIN NUMBER(COLOR)PIN NAME 
FUNCTION
1(YELLOW)D-RS-485-
2(WHITE)D+RS-485+
3(RED)VCCPower +
4(BLACK)GNDPower -

In case of user board, user can implement the communication circuit as follows. rs485_circuit 2

3.6.2 Expansion I/O Port

3.6.2.1 PIN Map Table

CAUTION

Since the Expansion I/O is not isolated, please use a separate Photo Coupler or Relay to implement an isolated circuit for safety or use it with caution.

PIN NUMBER(COLOR)PIN NAMEFUNCTION
GND (BLACK)GNDGND
1 (WHITE)Extended IO 1Switch, JOG, Action Next, Action Enable, Force Off, Stop, Pause, Alarm Out, Restart
2 (WHITE)Extended IO 2Switch, JOG, Action Next, Action Enable, Force Off, Stop, Pause, Alarm Out, Restart
3 (WHITE)Extended IO 3Action Enable, Force Off, Stop, Pause, Alarm Out, Restart
4 (WHITE)Extended IO 4Action Enable, Force Off, Stop, Pause, Alarm Out, Restart

For the detailed description of each I/O function, please refer to the 17Lf series User Manual Extended I/O Pin Mapextende_io_pinmapExtended IO WirePasted image 20240726162107

3.6.2.2 Circuit connection according to function
  • Switch/ JOG
    • Switch: When SW1 (Short Stroke Limit) or SW2 (Long Stroke Limit) is pressed, the motor moves to each position.
    • JOG: When SW1 (Short Stroke Limit) or SW2 (Long Stroke Limit) is pressed, the motor moves while pressing in each direction. extended_io_switch
  • Action Enable / Force Off / Stop / Pause / Restart
    • Action Enable: Start/stop the internal Action operation.
    • Force Off: On/Off the motor's driving force.
    • Stop: The motor stops and sets the stopped position as a Goal position.
    • Pause: The motor pauses, then actuator moves to the original Goal position when the switch is pressed again.
    • Restart: Restarts the servo actuator system. extended_io_single_sw
  • Alarm Out
    • Turns ON when a Hardware Error occurs. extened_io_ledextended_io_userboard
3.6.2.3 Isolated Circuit
  • Switch/ JOG / Action Enable / Force Off / Stop / Pause / RestartActuator/Mini 17Lf/img/image_20240729_103617
  • Alarm OutActuator/Mini 17Lf/img/image_20240729_103633