Skip to content

Lifecycle guideline for mightyZAP (17Lf Lineup)

Test Condition

Full Stroke / 50% Duty Rate / Pull spring LoaD (Rated full load)

Below data is not for Guarantee, but just reference data.

Life Cycle increasing Condition

  • Reducing Stroke : Direct inverse proportional ie) 10mm stroke, 2.7times longer lifecycle.
  • Reducing Duty Rate : Every 10% duty cycle reduced, 10% cycle increase ie) 30% duty cycle reduced, 30% cycle increase
  • Reducing Load : 10% load reduced, 5% lifecycle increase ie) 1kg load, 25% cycle increase

17Lf lifecycle img

Data

  • Test Duty Cycle : 50%

27mm Stroke

Model17Lf-20F-2717Lf-35F-2717Lf-70F-27
Rated Load20N35N70N
Max Speed117mm/s90mm/s30mm/s
Test Load
(by Srping Load)
2kg3.5kg7kg
1 Cycle stroke(mm)
Average Lifecycle2,400,0001,200,000400,000

37mm Stroke

Model17Lf-17F-3717Lf-27F-3717Lf-50F-37
Rated Load17N27N50N
Max Speed105mm/s82mm/s28mm/s
Test Load
(by Srping Load)
1.7kg2.7kg5kg
1 Cycle stroke(mm)
Average Lifecycle1,900,000960,000320,000

50mm Stroke

Model17Lf-17F-5017Lf-27F-5017Lf-50F-50
Rated Load17N27N50N
Max Speed105mm/s82mm/s28mm/s
Test Load
(by Srping Load)
1.7kg2.7kg5kg
1 Cycle stroke(mm)
Average Lifecycle1,550,000780,000260,000

87mm Stroke

Model17Lf-17F-8717Lf-27F-8717Lf-50F-87
Rated Load17N27N50N
Max Speed105mm/s82mm/s28mm/s
Test Load
(by Srping Load)
1.7kg2.7kg5kg
1 Cycle stroke(mm)
Average Lifecycle1,050,000520,000175,000

  • Described life cycle is not a guarantee as it may vary according to respective using conditions, difference of installation.
  • Current adjustment : If actuator’s force and speed are enough for customer’s application, customer may lengthen lifecycle by adjusting “Current amount” by mightyZAP manager software. Please note that speed and stall force will be decreased if "Goal Current or Current Limit" is decreased. (Please refer to the datasheet to see "Goal Current VS Stall Force graph".).